Solenoid Valves for Air VRA, VLA, VTA
- Easily adjust high- and low-fire settings
- Bypass bore available (optional)
- Suitable for pulse-fire applications (high duty cycle)
- A range of pipe sizes and opening/closing behaviors

Learn More:
Description Documentation Ordering Information
Ordering Information
| Model and Description | Price | Cart |
| VRA0-2N.T1 Fast Open/Fast Close; 3/8" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VRA1-2N.T1 Fast Open/Fast Close; ½" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VRA2-2N.T1 Fast Open/Fast Close; ¾" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VRA3-2N.T1 Fast Open/Fast Close; 1" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VRA35-2N.T1 Fast Open/Fast Close; 1¼" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VRA4-2N.T1 Fast Open/Fast Close; 1½" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VRA6-2N.T1 Fast Open/Fast Close; 2" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VRA6F-2N.T1 Fast Open/Fast Close; 2" pipe size; ANSI Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VRA7T-2N.T1 Fast Open/Fast Close; 2½" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VRA78-2N.T1 Fast Open/Fast Close; 2½", 3" pipe size; ANSI Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VLA0-2N.T1 Slow Open/Fast Close; 3/8" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VLA1-2N.T1 Slow Open/Fast Close; ½" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VLA2-2N.T1 Slow Open/Fast Close; ¾" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VLA3-2N.T1 Slow Open/Fast Close; 1" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VLA35-2N.T1 Slow Open/Fast Close; 1¼" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VLA4-2N.T1 Slow Open/Fast Close; 1½" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VLA6-2N.T1 Slow Open/Fast Close; 2" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VLA6F-2N.T1 Slow Open/Fast Close; 2" pipe size; ANSI Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VLA7T-2N.T1 Slow Open/Fast Close; 2½" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VLA78-2N.T1 Slow Open/Fast Close; 2½", 3" pipe size; ANSI Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VTA35-2N.T1 Slow Open/Slow Close; 1¼" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VTA4-2N.T1 Slow Open/Slow Close; 1½" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VTA6-2N.T1 Slow Open/Slow Close; 2" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VTA6F-2N.T1 Slow Open/Slow Close; 2" pipe size; ANSI Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VTA7T-2N.T1 Slow Open/Slow Close; 2½" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
||
| VTA78-2N.T1 Slow Open/Slow Close; 2½", 3" pipe size; ANSI Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
Description
Elektrogas solenoid valves for air VRA, VLA, and VTA are normally closed (open when energized) and are suitable for use with cold combustion air. They are ideal for high/low control of combustion air in industrial gas burners.